  • Strip 1/4” insulation from cable & motor wires, then scrape “bright”.
  • Remove any grease from wires for 2-3”.
  • Slide heat shrink tube over one end.
  • Insert wires into stakon connector.
  • Crimp to attach stakon connector to wires.
  • Pull lightly to test crimp.
  • Centre the tube over the stakon connector.
  • With low heat, shrink tube from the center, out.
  • When completely sealed, a slight glue amount should be visible.
  • Let cool a few minutes.